Penalties on the bill
Above a certain threshold, the reactive energy you draw is billed: an expense that produces nothing.
A capacitor bank sized to bring the power factor back to the right level.
Cut penalties and relieve your installation.
Fixed or automatic capacitor banks to improve the power factor: fewer penalties on the electricity bill and less stress on cables and transformers.
Above a certain threshold, the reactive energy you draw is billed: an expense that produces nothing.
A capacitor bank sized to bring the power factor back to the right level.
Reactive current needlessly loads transformers and cables, which heat up and reach their limits.
Less current in the installation: capacity freed up for new equipment.
Motors, air conditioning and processes do not run all the time: fixed compensation cannot keep up.
Automatic stepped banks driven by a reactive power controller.
Drives and electronics create harmonics that can damage poorly chosen capacitors.
Harmonic measurement before the design and detuned banks where necessary.
The capacitor bank supplies on site the reactive energy your motors need: the grid no longer has to carry it, and you no longer have to pay for it.
Every installation is delivered tested, labelled and documented, for simple operation and maintenance.
Recording of power factor, power and harmonics over several days.
It measures continuously and switches in the steps required.
Capacitors in steps, with suitable contactors and protection.
Detuning reactors where the supply is polluted.
A protected connection to the main switchboard, as close to the loads as possible.
An on-site measurement campaign and analysis of your electricity bills.
Reactive power to compensate, number of steps and harmonic protection.
Fixed compensation for stable loads, automatic for variable loads.
Installation, connection, controller setting and verification of the result.
Checks on capacitors and contactors, replacement of worn parts.
Reactive energy billed and penalties over recent months.
Recording of power and harmonics.
Rating, steps, type of bank and return on investment.
Installation, connection and controller setting.
Measurements after commissioning and follow-up of the bills.
This system can be covered by a preventive and corrective maintenance contract, with priority response on critical sites.
See the plansIt appears on your electricity bill. Send us your latest bills: we will tell you the amount at stake and the possible savings.
Often within a few months to two years, depending on the penalties paid. We estimate this before any commitment.
For stable loads, yes. If consumption varies during the day, an automatic bank avoids over-compensation.
Our engineers study your needs and reply within 48 business hours with initial technical and budget guidance.