Backup power when the grid fails.

  • StandbyAutomatic start on power failure
  • ATSMains / generator changeover with no one on site
  • TestedLoad tests before handover
Mains supply Generator set Automatic transfer switch AUTO Backed-up circuits
The challenges

What is at stake

Sizing, supply, installation and connection of generator sets with automatic transfer switches, to keep essential activities running during outages.

Power cuts give no warning

A mains failure stops business, medical equipment, the cold chain or production.

Our answer

Automatic start and restoration of essential circuits within seconds.

A correctly sized generator

Undersized, it trips when large motors start; oversized, it costs a lot and clogs up.

Our answer

A precise load assessment, taking inrush currents and planned extensions into account.

A generator that starts when it matters

A flat battery, stale diesel, clogged filters: a generator that is never tested is a generator that will not start.

Our answer

Regular tests, scheduled maintenance and tracking of running hours.

A safe changeover

The generator and the mains must never be connected at the same time.

Our answer

An automatic transfer switch with interlocking, adjusted and tested.

Architecture

An architecture designed in layers

Mains, transfer switch and generator form a single system: as soon as the mains fails the generator starts and the switch changes over, then everything returns to normal automatically when the mains comes back.

Every installation is delivered tested, labelled and documented, for simple operation and maintenance.

  1. Layer 01

    Mains supply

    Continuous monitoring of mains voltage and frequency.

  2. Layer 02

    Generator set

    Diesel engine, alternator, soundproofed canopy and fuel reserve.

  3. Layer 03

    Transfer switch

    Automatic mains / generator changeover with a safety interlock.

  4. Layer 04

    Backed-up circuits

    A board of priority feeders: safety, refrigeration, IT, medical.

  5. Layer 05

    Monitoring

    Alarms, running hours and fuel level viewable remotely.

Services

Our services

01

Power assessment and sizing

Survey of loads and inrush currents, and choice of the right rating.

02

Supply and installation

Canopied or room-installed generator, plinth, exhaust and ventilation.

03

Automatic transfer switches

Automatic changeover, time delays and mains return adjusted.

04

Connection and load testing

Connection to the switchboards and load-bank tests before handover.

05

Periodic servicing

Oil changes, filters, batteries and tests on the manufacturer’s schedule.

06

Troubleshooting

Rapid response to breakdowns, including on critical sites.

Technologies we master
Diesel generatorsAutomatic transfer switchesLoad testingMonitoring
Method

Our method, step by step

  1. 1

    Power assessment

    Loads to back up, motor starts, planned extensions.

  2. 2

    Selection & siting

    Rating, canopy, location, exhaust and fuel.

  3. 3

    Installation

    Installation, connection, transfer switch and backed-up circuit board.

  4. 4

    Load testing

    Simulated mains failure, changeovers and measured performance under load.

  5. 5

    Maintenance

    Maintenance contract and periodic tests.

Standards

Compliance with standards

  • ISO 8528Generator sets
  • IEC 60947-6-1Automatic transfer switches
  • IEC 60364-5-55Standby generating sets
Deliverables

What we hand over to you

  • Sizing calculation
  • Connection and transfer switch diagrams
  • Load test report
  • Maintenance logbook
  • Operating instructions

Maintenance & 24/7 support

This system can be covered by a preventive and corrective maintenance contract, with priority response on critical sites.

See the plans
FAQ

Your questions

Another question? Our engineers will answer.

How long does it take to restore power?

A few seconds is usually enough for the generator to start and the switch to change over. For truly uninterrupted power, it is combined with a UPS.

Does the whole building need backup?

Not necessarily. Backing up only essential circuits allows a smaller, cheaper generator.

Do you maintain existing generators?

Yes, whatever the brand: assessment, overhaul and maintenance contract.