Power & energy

UPS & protected power networks

Clean, uninterrupted power for your critical equipment.

  • On-lineDouble conversion
  • 0 msNo break at changeover
  • BypassMaintenance without shutdown
OutageDisturbed mains Stable output Bypass 100 %ON-LINE On-line UPS Batteries Critical equipment
The challenges

What is at stake

UPS, batteries and protected power distribution for server rooms, security, medical and process equipment: no micro-cuts, no data loss, the right autonomy.

Sensitive equipment

Servers, medical equipment, security systems and controllers cannot tolerate even a brief interruption.

Our answer

Double-conversion on-line UPSs: the output stays stable whatever happens upstream.

A disturbed mains supply

Voltage dips, surges and noise damage power supplies and cause random failures.

Our answer

Voltage and frequency regulated at all times, disturbances filtered out.

Holding on until backup takes over

The UPS must hold until the generator starts, or allow the servers to shut down cleanly.

Our answer

Autonomy calculated on your loads and automatic server shutdown during long outages.

Batteries under watch

Batteries age without warning: real autonomy shrinks year after year.

Our answer

Battery tests, monitoring and planned replacement.

Architecture

An architecture designed in layers

The UPS sits between the mains and your critical equipment: it rebuilds a perfect voltage and switches to batteries without the slightest interruption.

Every installation is delivered tested, labelled and documented, for simple operation and maintenance.

  1. Layer 01

    Mains & generator

    Normal supply, with generator backup upstream.

  2. Layer 02

    On-line UPS

    Rectifier, inverter and static switch: a stable output at all times.

  3. Layer 03

    Batteries

    Sized autonomy, batteries in cabinets or racks, monitored.

  4. Layer 04

    Maintenance bypass

    Work on the UPS without cutting power to the equipment.

  5. Layer 05

    UPS-backed network

    A dedicated, labelled board and sockets reserved for critical equipment.

Services

Our services

01

Autonomy sizing

Autonomy calculated on the actual load and the required bridging time.

02

Single-phase and three-phase UPS

From small rack UPSs to redundant three-phase systems.

03

Dedicated protected power networks

Dedicated circuits and sockets, separate from the normal supply and identified.

04

Battery banks

Batteries suited to the autonomy and the environment, installed and checked.

05

Maintenance bypass

Maintenance and replacement of the UPS with no equipment shutdown.

06

Monitoring and alerts

Alerts by e-mail or SNMP and automatic server shutdown.

Technologies we master
Online UPSBatteriesBypassProtected power distribution
Method

Our method, step by step

  1. 1

    Load measurement

    Actual power, equipment to protect, desired autonomy.

  2. 2

    Sizing

    Rating, redundancy, batteries, bypass and distribution.

  3. 3

    Installation

    UPS, batteries, UPS-backed board and connections.

  4. 4

    Testing

    Simulated outage, measured autonomy, alerts checked.

  5. 5

    Follow-up

    Monitoring, battery tests and maintenance.

Standards

Compliance with standards

  • IEC 62040-3UPS performance (VFI)
  • IEC 62040-1UPS safety
  • IEC 60896Stationary batteries
  • IEC 60364Electrical installations and earthing
Deliverables

What we hand over to you

  • Power and autonomy calculation
  • UPS-backed network diagram
  • Outage test report
  • Initial battery readings
  • Alert and automatic shutdown settings

Maintenance & 24/7 support

This system can be covered by a preventive and corrective maintenance contract, with priority response on critical sites.

See the plans
FAQ

Your questions

Another question? Our engineers will answer.

UPS or generator?

They complement each other: the UPS provides instant continuity, the generator takes over for long outages.

How much autonomy should we plan?

Enough for the generator to start, or to shut the servers down cleanly if there is no generator. We calculate it on your actual loads.

How often should the batteries be replaced?

Depending on the technology and temperature, often every 3 to 5 years. Regular tests make it possible to replace them at the right time.

Let’s talk about your site

A project, an installation to take over or to maintain?

Our engineers study your needs and reply within 48 business hours with initial technical and budget guidance.